Showing posts with label In line splice for armor cable. Show all posts
Showing posts with label In line splice for armor cable. Show all posts

Monday, April 21, 2014

HVSA-3 Conductor Cable Splice Kit


HVSA-3

In-Line Splices for 3/C Armor Cable (5-15 kV)


TE Connectivity’s Raychem three conductor cable splice kits are designed to rebuild all layers of the
cable. These kits meet the same performance criteria as our single conductor splice kits
  • Rated to IEEE 404.
  • For use on copper tape, wire shield, lead sheath, and UniShield cables.









Common HVSA-3 Ordering Options for 3 Conductor Cable Splice



Rated for use at 5/8 kV


HVSA-3-821S is supplied for a 5 kV Conductor Size range of #6-2/0 and an 8 kV Conductor Size Range of #6-#2. It has a Min.-Max Insulation Diameter of 9-17 mm (A) with a Minimum Jacket O.D.of 
23 mm (B). The Maximum Connector O.D. is 13 mm (C) and the Maximum Connector Length is 
76 mm (D).

HVSA-3-822S is supplied for a 5 kV Conductor Size range of 3/0-300 and an 8 kV Conductor Size Range of #1-4/0. It has a Min.-Max Insulation Diameter of 14-23 mm (A) with a Minimum Jacket O.D.of 
33 mm (B). The Maximum Connector O.D. is 19 mm (C) and the Maximum Connector Length is 
108 mm (D).

HVSA-3-823S is supplied for a 5 kV Conductor Size range of 350-750 and an 8 kV Conductor Size Range of 250-350. It has a Min.-Max Insulation Diameter of 20-30 mm (A) with a Minimum Jacket O.D.of 
39 mm (B). The Maximum Connector O.D. is 28 mm (C) and the Maximum Connector Length is 
152 mm (D).

HVSA-3-824S is supplied for a 5 kV Conductor Size range of 1000-1500 and an 8 kV Conductor Size Range of 500-750. It has a Min.-Max Insulation Diameter of 25-41 mm (A) with a Minimum Jacket O.D.of 
39 mm (B). The Maximum Connector O.D. is 37 mm (C) and the Maximum Connector Length is 
203 mm (D).

HVSA-3-825S is supplied for a 8 kV Conductor Size range of 1750-1000 . It has a Min.-Max Insulation Diameter of 33-57 mm (A) with a Minimum Jacket O.D.of 61 mm (B). The Maximum Connector O.D. is 47 mm (C) and the Maximum Connector Length is 203 mm (D)



Rated for use at 15 kV

HVSA-3-1521S is supplied for a 15 kV Conductor Size range of #2-4/0. It has a Min.-Max Insulation Diameter of 17-27 mm (A) with a Minimum Jacket O.D.of 39 mm (B). The Maximum Connector O.D. is 23 mm (C) and the Maximum Connector Length is 108 mm (D).

HVSA-3-1522S is supplied for a 15 kV Conductor Size range of 250-350. It has a Min.-Max Insulation Diameter of 23-33 mm (A) with a Minimum Jacket O.D.of 61 mm (B). The Maximum Connector O.D. is 29 mm (C) and the Maximum Connector Length is 140 mm (D).

HVSA-3-1523S is supplied for a 15 kV Conductor Size range of 500-750. It has a Min.-Max Insulation Diameter of 28-41 mm (A) with a Minimum Jacket O.D.of 61 mm (B). The Maximum Connector O.D. is 41 mm (C) and the Maximum Connector Length is 203 mm (D)

HVSA-3-1524S is supplied for a 15 kV Conductor Size range of 750-1000. It has a Min.-Max Insulation Diameter of 32-46 mm (A) with a Minimum Jacket O.D.of 61 mm (B). The Maximum Connector O.D. is 47 mm (C) and the Maximum Connector Length is 203 mm (D).