Contact Us

We are Elite Distributors for Raychem / Tyco Electronics and
Master Distributors for Covalence Heat Shrink Sleeves
Call: 936/321-3333
Email: Stacey@jsicoatings.com or Steve@jsicoatings.com
Visit our official site: www.heatshrinksleeves.com
Pipeline Blog: blog.heatshrinksleeves.com
Showing posts with label Raychem cold shrink. Show all posts
Showing posts with label Raychem cold shrink. Show all posts

Tuesday, January 12, 2016

RVS Roll On Splice Seal

Rayvolve Cold Applied Splice Seal

rayvolve

     Rayvolve RVS Splice cover kits are the easy roll on way to insulate and seal cable connections up to 1000 volts.  The gripping force of the specially formulated EPDM elastomer combines with the high performance sealant to form a water resistant, insulating sleeve that is UL listed and CSA certified for direct burial application over in line compression connectors.

     Rayvolve splice cover sleeves feature a dual wall design with an entrapped lubricant, making installation fast and simple.  The elastomeric sleeve rolls onto the cable with minimal effort, even at temperatures below -15F. 
 
     The cable can be energized immediately.  It is ideal for use where gas and electric heating devices are not approved or allowed due to safety concerns.

rvs sizing

     RVS-11 for #8 - 2/0
     RVS-12 for 1/0 to 250
     RVS-13 for 250-600
     RVS-14 for 600-1000

Monday, April 21, 2014

CSJA JCN/EG; All-in-one Cold Shrinkable Joints


CSJA JCN/EG

In-Line Cold Shrinkable Joints Specifically for 1/C Jacketed Concentric Neutral Cables (15-35 kV)


TE’s Raychem “All-in-One” CSJA is a cold shrinkable joint for 15 kV through 35 kV. It is designed to
splice jacketed concentric neutral (JCN) cables.
  • Cable joint has a pre-expanded EPDM rejacketing sleeve and an integrated neutral sock.
    The “All-in-One” design is easy to install with minimal steps and short installation time
  • A pre-expanded, single-piece silicone rubber joint body with high mechanical expansion capability
    allows a wide application range
  • An ergonomically designed spiral holdout provides a smooth installation with low release forces.
  • Total length of the splice body on the holdout is 14 to 19 inches providing a compact design.
  • The Silicone rubber body provides high dielectric strength, high tear strength, low tension set, and
    excellent low temperature recovery
  • Integrated electrical stress control enhanced by factory molded stress cones and Faraday cage.
  • Void filling stress relief mastics are not necessary.
  • Proven shield continuity concept. The neutral wires are connected externally. The integrated pre-expanded neutral sock is connected to the neutral wires by a constant force spring. This provides
    the metallic shielding system to the cable joint.
  • The joint accepts both mechanical and compression connectors.
  • Meets IEEE-404 requirements for 15 kV through 35 kV.
 Each silicone splice body is factory tested to include AC withstand and partial discharge in
accordance with IEEE-404 production tests.







Selection Information:






 Commonly used CSJA JCN/EG Joints Without Connector

CSJA-JCN/EG-1511 is supplied with a Voltage Class of 15 kV and a Nominal Cable Range of #2-350. The Insulation O.D. range is 17.5-30.5 mm (A) with a Maximum Jacket O.D. of 38.1 mm (B). The Maximum Connector Dimensions include an O.D. of 33 mm (C) and a Length of 140 mm (D).

CSJA-JCN/EG-1512 is supplied with a Voltage Class of 15 kV and a Nominal Cable Range of 4/0-750. The Insulation O.D. range is 22.1-35.6 mm (A) with a Maximum Jacket O.D. of 46 mm (B). The Maximum Connector Dimensions include an O.D. of 38 mm (C) and a Length of 140 mm (D).

CSJA-JCN/EG-1513 is supplied with a Voltage Class of 15 kV and a Nominal Cable Range of 350-1000. The Insulation O.D. range is 26.2-40 mm (A) with a Maximum Jacket O.D. of 52.1 mm (B). The Maximum Connector Dimensions include an O.D. of 42 mm (C) and a Length of 170 mm (D).

CSJA-JCN/EG-1514 is supplied with a Voltage Class of 15 kV and a Nominal Cable Range of 750-1250. The Insulation O.D. range is 32.5-52 mm (A) with a Maximum Jacket O.D. of 66 mm (B). The Maximum Connector Dimensions include an O.D. of 47 mm (C) and a Length of 200 mm (D).

CSJA-JCN/EG-2812 is supplied with a Voltage Class of 28 kV and a Nominal Cable Range of #1-500. The Insulation O.D. range is 22.1-35.6 mm (A) with a Maximum Jacket O.D. of 46 mm (B). The Maximum Connector Dimensions include an O.D. of 38 mm (C) and a Length of 140 mm (D).

CSJA-JCN/EG-2813 is supplied with a Voltage Class of 28 kV and a Nominal Cable Range of 4/0-750. The Insulation O.D. range is 26.2-40 mm (A) with a Maximum Jacket O.D. of 52.1 mm (B). The Maximum Connector Dimensions include an O.D. of 42 mm (C) and a Length of 170 mm (D)

 CSJA-JCN/EG-2814 is supplied with a Voltage Class of 28 kV and a Nominal Cable Range of 500-1250. The Insulation O.D. range is 32.5-52 mm (A) with a Maximum Jacket O.D. of 66 mm (B). The Maximum Connector Dimensions include an O.D. of 47 mm (C) and a Length of 200 mm (D).

 CSJA-JCN/EG-3513 is supplied with a Voltage Class of 35 kV and a Nominal Cable Range of 1/0-350. The Insulation O.D. range is 26.2-37.8 mm (A) with a Maximum Jacket O.D. of 52.1 mm (B). The Maximum Connector Dimensions include an O.D. of 35.6 mm (C) and a Length of 140 mm (D).

CSJA-JCN/EG-3514 is supplied with a Voltage Class of 35 kV and a Nominal Cable Range of 350-1000. The Insulation O.D. range is 34.54-52 mm (A) with a Maximum Jacket O.D. of 66 mm (B). The Maximum Connector Dimensions include an O.D. of 50 mm (C) and a Length of 200 mm (D)

CSJA-JCN/EG-3515 is supplied with a Voltage Class of 35 kV and a Nominal Cable Range of 750-1250. The Insulation O.D. range is 41.4-60 mm (A) with a Maximum Jacket O.D. of 66 mm (B). The Maximum Connector Dimensions include an O.D. of 60 mm (C) and a Length of 200 mm (D)



Commonly used CSJA JCN/EG Joints with Copper Mechanical ShearBolt Connector

CSJA-JCN/EG-1511M1 is supplied with a Voltage Class of 15 kV and a Nominal Cable Range of 2/0-350. The Insulation O.D. range is 17.5-30.5 mm (A) with a Maximum Jacket O.D. of 38.1 mm (B). The Diameter Over Cable Conductor range is 9.5-18.7 mm.

CSJA-JCN/EG-1512M1 is supplied with a Voltage Class of 15 kV and a Nominal Cable Range of 4/0-500. The Insulation O.D. range is 22.1-35.6 mm (A) with a Maximum Jacket O.D. of 46 mm (B). The Diameter Over Cable Conductor range is 9.5-18.7 mm.

CSJA-JCN/EG-1512M2 is supplied with a Voltage Class of 15 kV and a Nominal Cable Range of 350-750. The Insulation O.D. range is 22.1-35.6 mm (A) with a Maximum Jacket O.D. of 46 mm (B). The Diameter Over Cable Conductor range is 14.5-24 mm.

CSJA-JCN/EG-1513M2 is supplied with a Voltage Class of 15 kV and a Nominal Cable Range of 350-750. The Insulation O.D. range is 26.2-40 mm (A) with a Maximum Jacket O.D. of 52.1 mm (B). The Diameter Over Cable Conductor range is 14.5-24 mm.

 CSJA-JCN/EG-2812M1 is supplied with a Voltage Class of 28 kV and a Nominal Cable Range of 2/0-500. The Insulation O.D. range is 22.1-35.6 mm (A) with a Maximum Jacket O.D. of 46 mm (B). The Diameter Over Cable Conductor range is 9.5-18.7 mm.

CSJA-JCN/EG-2813M2 is supplied with a Voltage Class of 28 kV and a Nominal Cable Range of 350-750. The Insulation O.D. range is 26.2-40 mm (A) with a Maximum Jacket O.D. of 52.1 mm (B). The Diameter Over Cable Conductor range is 14.5-24 mm.

CSJA-JCN/EG-2814M2 is supplied with a Voltage Class of 28 kV and a Nominal Cable Range of 500-750. The Insulation O.D. range is 26.2-40 mm (A) with a Maximum Jacket O.D. of 52.1 mm (B). The Diameter Over Cable Conductor range is 14.5-24 mm.

CSJA-JCN/EG-3513M1 is supplied with a Voltage Class of 35 kV and a Nominal Cable Range of 2/0-350. The Insulation O.D. range is 26.2-37.8 mm (A) with a Maximum Jacket O.D. of 52.1 mm (B). The Diameter Over Cable Conductor range is 9.5-18.7 mm.

CSJA-JCN/EG-3514M2 is supplied with a Voltage Class of 35 kV and a Nominal Cable Range of 350-750. The Insulation O.D. range is 34.54-52 mm (A) with a Maximum Jacket O.D. of 66 mm (B). The Diameter Over Cable Conductor range is 14.5-24 mm. 













































3/C CSJA; Cold Shrinkable Joint Armored Cables

3/C CSJA

Cold Shrinkable Joint for 3/C Armored Cables (15-35 kV)

Raychem’s CSJA cold shrinkable joint for 15 kV through 35 kV is designed to splice 3/C armored
cables. The splice consists of three pre-expanded silicone bodies on a unique holdout and a
separate rejacketing system.

This design is easy to install with minimal steps and a short installation time. The rejacketing system
is a cold-applied wraparound sleeve designed to seal the entire splice and provide mechanical and
environmental protection for direct buried installations. Both mechanical and compression connectors
can be used.
  • A pre-expanded, single piece silicone rubber body with high mechanical expansion capability which allows a wide application range.
  • An ergonomically designed spiral holdout provides a smooth installation with low release forces.
  • Integrated electrical stress control enhanced by factory molded stress cones and a Faraday cage.
  • The joint and rejacketing system are both qualified to the latest revision of IEEE-404.
  • Each silicone splice body is factory tested to include AC withstand and partial discharge in accordance with IEEE-404 production tests.
  • The GMRS rejacketing system is a cold-applied wrap around sleeve that eliminates parking distance required with traditional rejacketing. It is designed to seal the entire splice and provide mechanical and environmental protection for direct buried and submersible applications.



CSJA 3/C Reference Image


Common CSJA 3/C Joint Sizes Without Connector (see above image as a reference)
CSJA-3-1521-ARMR has a voltage class of 15 kV. This Shrinkable Joint has a minimum insulation OD of 17.5 mm and a maximum of 30.5 mm (A). It's Connector Dimensions include a maximum OD of 33 mm (C) and a maximum length of 140 mm (D). The Required Installation Space for this particular CSJA is
 1650 mm (M).

CSJA-3-1522-ARMR has a voltage class of 15 kV. This Shrinkable Joint has a minimum insulation OD of 22.1 mm and a maximum of 35.6 mm (A). It's Connector Dimensions include a maximum OD of 38 mm (C) and a maximum length of 140 mm (D). The Required Installation Space for this particular CSJA is
 1650 mm (M).

CSJA-3-1523-ARMR has a voltage class of 15 kV. This Shrinkable Joint has a minimum insulation OD of 26.2 mm and a maximum of 40 mm (A). It's Connector Dimensions include a maximum OD of 42 mm (C) and a maximum length of 170 mm (D). The Required Installation Space for this particular CSJA is
 1800 mm (M).


CSJA-3-2822-ARMR has a voltage class of 28 kV. This Shrinkable Joint has a minimum insulation OD of 22.1 mm and a maximum of 35.6 mm (A). It's Connector Dimensions include a maximum OD of 38 mm (C) and a maximum length of 140 mm (D). The Required Installation Space for this particular CSJA is
 1650 mm (M).
CSJA-3-2823-ARMR has a voltage class of 28 kV. This Shrinkable Joint has a minimum insulation OD of 26.2 mm and a maximum of 40 mm (A). It's Connector Dimensions include a maximum OD of 42 mm (C) and a maximum length of 170 mm (D). The Required Installation Space for this particular CSJA is
 1800 mm (M).
CSJA-3-3523-ARMR has a voltage class of 35 kV. This Shrinkable Joint has a minimum insulation OD of 26.2 mm and a maximum of 37.8 mm (A). It's Connector Dimensions include a maximum OD of 35.6 mm (C) and a maximum length of 140 mm (D). The Required Installation Space for this particular CSJA is
 1800 mm (M).

CSJA-3-3524-ARMR has a voltage class of 35 kV. This Shrinkable Joint has a minimum insulation OD of 34.5 mm and a maximum of 40.6 mm (A). It's Connector Dimensions include a maximum OD of 50 mm (C) and a maximum length of 200 mm (D). The Required Installation Space for this particular CSJA is
 1800 mm (M).

Common CSJA 3/C Joint Sizes With Copper Shearbolt Connector 
CSJA-3-1521M1-ARMR has a voltage class of 15 kV and a Nominal Cable Range of 2/0-350. The minimum insulation OD is 17.5 mm with a maximum of 30.5 mm. There is a minimum diameter over cable conductor of 9.5 mm and a max of 18.7 mm.

CSJA-3-1522M1-ARMR has a voltage class of 15 kV and a Nominal Cable Range of 4/0-500. The minimum insulation OD is 22.1 mm with a maximum of 35.6 mm. There is a minimum diameter over cable conductor of 9.5 mm and a max of 18.7 mm.

CSJA-3-1522M2-ARMR has a voltage class of 15 kV and a Nominal Cable Range of 350-750. The minimum insulation OD is 22.1 mm with a maximum of 35.6 mm. There is a minimum diameter over cable conductor of 14.5 mm and a max of 24 mm.

CSJA-3-1523M3-ARMR has a voltage class of 15 kV and a Nominal Cable Range of 500-1000. The minimum insulation OD is 26.2 mm with a maximum of 40 mm. There is a minimum diameter over cable conductor of 18.7 mm and a max of 29.3 mm.

CSJA-3-2822M1-ARMR has a voltage class of 28 kV and a Nominal Cable Range of 2/0-500. The minimum insulation OD is 22.1 mm with a maximum of 35.6 mm. There is a minimum diameter over cable conductor of 9.5 mm and a max of 18.7 mm.

CSJA-3-2823M2-ARMR has a voltage class of 28 kV and a Nominal Cable Range of 350-750. The minimum insulation OD is 26.2 mm with a maximum of 40 mm. There is a minimum diameter over cable conductor of 14.5 mm and a max of 24 mm.

CSJA-3-3523M1-ARMR has a voltage class of 35 kV and a Nominal Cable Range of 2/0-350. The minimum insulation OD is 26.2 mm with a maximum of 37.8 mm. There is a minimum diameter over cable conductor of 9.5 mm and a max of 18.7 mm.

CSJA-3-3524M2-ARMR has a voltage class of 35 kV and a Nominal Cable Range of 350-500. The minimum insulation OD is 34.5 mm with a maximum of 40.6 mm. There is a minimum diameter over cable conductor of 14.5 mm and a max of 24 mm.

*Min/max diameter over cable conductor accepted by the copper mechanical connector.

Common CSJA 3/C Joint Sizes With Aluminum Shearbolt Connector
CSJA-3-1521M4-ARMR has a voltage class of 15 kV and a Nominal Cable Range of #2-3/0. The minimum insulation OD is 17.5 mm with a maximum of 30.5 mm. There is a minimum diameter over cable conductor of 6.8 mm and a max of 11.9 mm.

CSJA-3-1521M5-ARMR has a voltage class of 15 kV and a Nominal Cable Range of #2-350. The minimum insulation OD is 17.5 mm with a maximum of 30.5 mm. There is a minimum diameter over cable conductor of 6.8 mm and a max of 17.3 mm.

CSJA-3-1522M6-ARMR has a voltage class of 15 kV and a Nominal Cable Range of 4/0-500. The minimum insulation OD is 22.1 mm with a maximum of 35.6 mm. There is a minimum diameter over cable conductor of 10.7 mm and a max of 20.6 mm.

CSJA-3-1522M7-ARMR has a voltage class of 15 kV and a Nominal Cable Range of 500-750. The minimum insulation OD is 22.1 mm with a maximum of 35.6 mm. There is a minimum diameter over cable conductor of 18.7 mm and a max of 25.3 mm.

CSJA-3-1523M8-ARMR has a voltage class of 15 kV and a Nominal Cable Range of 350-750. The minimum insulation OD is 26.2 mm with a maximum of 40 mm. There is a minimum diameter over cable conductor of 15.7 mm and a max of 25.3 mm.

CSJA-3-2822M5-ARMR has a voltage class of 28 kV and a Nominal Cable Range of #1-350. The minimum insulation OD is 22.1 mm with a maximum of 35.6 mm. There is a minimum diameter over cable conductor of 6.8 mm and a max of 17.3 mm.

CSJA-3-2822M6-ARMR has a voltage class of 28 kV and a Nominal Cable Range of 4/0-500. The minimum insulation OD is 22.1 mm with a maximum of 35.6 mm. There is a minimum diameter over cable conductor of 10.7 mm and a max of 20.6 mm.

CSJA-3-2823M8-ARMR has a voltage class of 28 kV and a Nominal Cable Range of 350-750. The minimum insulation OD is 26.2 mm with a maximum of 40 mm. There is a minimum diameter over cable conductor of 15.7 mm and a max of 25.3 mm.

CSJA-3-3523M5-ARMR has a voltage class of 35 kV and a Nominal Cable Range of 1/0-350. The minimum insulation OD is 26.2 mm with a maximum of 37.8 mm. There is a minimum diameter over cable conductor of 6.8 mm and a max of 17.3 mm.

CSJA-3-3524M8-ARMR has a voltage class of 35 kV and a Nominal Cable Range of 350-500. The minimum insulation OD is 34.5 mm with a maximum of 40.6 mm. There is a minimum diameter over cable conductor of 15.7 mm and a max of 25.3 mm.

*Min/max diameter over cable conductor accepted by the aluminum mechanical connector.