Cold-Applied Elbow Seal CES
600 Amp (15-35 kV) class for 1/C Jacketed Cables
TE Connectivity’s Raychem CES Cold-Applied Elbow Sealing Kit is used for sealing power cables
where elbows or other cable accessories are installed. The CES is applied in 15-35 kV, 600A
applications. It protects underground cable from moisture and airborne contaminants, and is suitable
for both direct burial and submersible applications.
where elbows or other cable accessories are installed. The CES is applied in 15-35 kV, 600A
applications. It protects underground cable from moisture and airborne contaminants, and is suitable
for both direct burial and submersible applications.
The kit consists of a factory-expanded tubular EPDM rubber sleeve on a spiral holdout, along with
strips of mastic which are used to help create the seal.
strips of mastic which are used to help create the seal.
Designed for easy field installation After applying the mastic and cable accessory, the spiral
holdout is simply pulled clear. The jacket will compress and, in combination with the mastic, form an
environmental seal.
holdout is simply pulled clear. The jacket will compress and, in combination with the mastic, form an
environmental seal.
- Highly elastic EPDM formulation enables wide cable application ranges. Just three products are
able to cover the most common range of cable, 15 kV #2-35 kV 1250 kcmil - An ergonomically designed spiral holdout provides a smooth installation with low release forces
- No open flame or heat source is required for installation
- Meets IEEE 404 jacket sealing requirements
- Thick walled tube resists puncture and damage
- Resistant to fungus, acids, and alkalies
Standard CES Cold-Applied Elbow Sealing Kit Options:
ELB-600-CES-1 has an Expanded Tube Length of 127 mm and a Relaxed Tube Length of 150 mm. The Expanded Tube Diameter is 57 mm while the Inner Diameter of the Holdout is 53 mm. ELB-600-CES-1 is supplied for a Cable Size range of 2-4/0 AWG at a 15 kV Class, 2-2/0 AWG at a 25 kV Class, and
1/0 AWG at Class 35 kV. The Minimum Diameter of the Seal is 24 mm.
ELB-600-CES-2 has an Expanded Tube
Length of 171 mm and a Relaxed Tube Length of 200 mm. The Expanded Tube
Diameter is 75 mm while the Inner Diameter of the Holdout is 70 mm.
ELB-600-CES-2 is supplied for a Cable Size range of 2/0-1000 kcmil at a 15 kV
Class, 1/0 AWG-750 kcmil at a 25 kV Class, and 1/0 AWG-500 kcmil at Class 35 kV. The Minimum Diameter of the Seal is 33 mm.
ELB-600-CES-3 has an Expanded Tube
Length of 190 mm and a Relaxed Tube Length of 225 mm. The Expanded Tube
Diameter is 105 mm while the Inner Diameter of the Holdout is 98 mm.
ELB-600-CES-3 is supplied for a Cable Size range of 750-1500 kcmil at a 15 kV
Class, 600-1250 kcmil at a 25 kV Class, and 350-1250 kcmil at Class 35 kV. The Minimum Diameter of the Seal is 41 mm.