Contact Us

We are Elite Distributors for Raychem / Tyco Electronics and
Master Distributors for Covalence Heat Shrink Sleeves
Call: 936/321-3333
Email: Stacey@jsicoatings.com or Steve@jsicoatings.com
Visit our official site: www.heatshrinksleeves.com
Pipeline Blog: blog.heatshrinksleeves.com

Monday, April 21, 2014

Splices of Teck Cable (1000V - 15 kV)



TECK Splices for Teck Cable rated for use from 1000 Volts up to 15 Kilovolts

Designed specifically for TECK power cable, the Raychem TECK splice kits are easy to install and
are ideal for underground and cable tray applications. The splice is protected from moisture and
mechanical damage by two layers of adhesive-lined WCSM heavy-wall tubing and one layer of
CRSM wraparound sleeve.
  • Positive environmental sealing
  • Complete grounding and bonding
  • Fast, easy installation
  • Slim profile
CSA certified to C22 2, No 198 2 For use on 1/C and 4/C 1000-V TECK cable and 3/C 5 kV
TECK cable.



Common TECK Sizes for Low-Voltage 1/C
TECK-10 supplied with a nominal cable range of #6-#1 AWG. TECK-10 has an Insulation Diameter minimum of 10 mm and a maximum of 15 mm. The Inner Jacket Diameter Range is 10-20 mm with an Outside Jacket Diameter Range of 20 to 30 mm. TECK-10's Maximum Connector Length is 50 mm and the total Splice Installed Length is 560 mm.

TECK-11 supplied with a nominal cable range of 1/0-3/0 AWG. TECK-11 has an Insulation Diameter minimum of 10 mm and a maximum of 20 mm. The Inner Jacket Diameter Range is 15-25 mm with an Outside Jacket Diameter Range of 25 to 30 mm. TECK-11's Maximum Connector Length is 90 mm and the total Splice Installed Length is 560 mm. 

TECK-12 supplied with a nominal cable range of 4/0-350 MCM. TECK-12 has an Insulation Diameter minimum of 15 mm and a maximum of 25 mm. The Inner Jacket Diameter Range is 20-30 mm with an Outside Jacket Diameter Range of 30 to 35 mm. TECK-12's Maximum Connector Length is 125 mm and the total Splice Installed Length is 635 mm. 

TECK-13 supplied with a nominal cable range of 400-750 MCM. TECK-13 has an Insulation Diameter minimum of 20 mm and a maximum of 30 mm. The Inner Jacket Diameter Range is 30-40 mm with an Outside Jacket Diameter Range of 35 to 45 mm. TECK-13's Maximum Connector Length is 190 mm and the total Splice Installed Length is 735 mm.

TECK-13 supplied with a nominal cable range of 1000-2000 MCM. TECK-14 has an Insulation Diameter minimum of 30 mm and a maximum of 55 mm. The Inner Jacket Diameter Range is 40-60 mm with an Outside Jacket Diameter Range of 50 to 70 mm. TECK-14's Maximum Connector Length is 205 mm and the total Splice Installed Length is 1015 mm. 

Common TECK Sizes for Low-Voltage 4/C
TECK-41 supplied with a nominal cable range of #14-#4 AWG. TECK 41 has an Inner Jacket Diameter Range of 15-30 mm with an Outer Jacket Diameter Range of 20 to 35 mm. TECK 41 includes a Maximum Connector Length of 50 mm and a Splice Installed Length of 650 mm.

TECK-42 supplied with a nominal cable range of #2-3/0 AWG. TECK 42 has an Inner Jacket Diameter Range of 25-45 mm with an Outer Jacket Diameter Range of 35 to 55 mm. TECK 42 includes a Maximum Connector Length of 75 mm and a Splice Installed Length of 650 mm.

TECK-43 supplied with a nominal cable range of 4/0-400 MCM. TECK 43 has an Inner Jacket Diameter Range of 40-65 mm with an Outer Jacket Diameter Range of 50 to 70 mm. TECK 43 includes a Maximum Connector Length of 100 mm and a Splice Installed Length of 1015 mm. 

TECK-44 supplied with a nominal cable range of 500-1000 MCM. TECK 44 has an Inner Jacket Diameter Range of 50-90 mm with an Outer Jacket Diameter Range of 65 to 100 mm. TECK 44 includes a Maximum Connector Length of 165 mm and a Splice Installed Length of 1015 mm.  

Common TECK Sizes for 5 kV Unshielded 3/C
TECK-531 supplied with a nominal cable range of #2-4/0 AWG. TECK-531 has an Insulation Diameter minimum of 10 mm and a maximum of 20 mm. The Inner Jacket Diameter Range is 30-50 mm with an Outside Jacket Diameter Range of 40 to 60 mm. TECK-531's Maximum Connector Length is 90 mm and the total Splice Installed Length is 1015 mm.

TECK-532 supplied with a nominal cable range of 250-750 MCM. TECK-532 has an Insulation Diameter minimum of 15 mm and a maximum of 30 mm. The Inner Jacket Diameter Range is 45-75 mm with an Outside Jacket Diameter Range of 55 to 85 mm. TECK-532's Maximum Connector Length is 150 mm and the total Splice Installed Length is 1220 mm. 

Common TECK Sizes for 15 kV Shielded 3/C
HVSA-3-1521S-TECK supplied with a nominal cable range of #2-4/0 AWG. It requires an Insulation Diameter minimum of 17 mm and a maximum of 27 mm. The Inner Jacket Diameter Range is 45-115 mm with an Outside Jacket Diameter Range of 65 to 165 mm. The Maximum Connector Length is 105 mm and the total Splice Installed Length is 1830 mm.  

HVSA-3-1522S-TECK supplied with a nominal cable range of 250-350 kcmil. It requires an Insulation Diameter minimum of 23 mm and a maximum of 33 mm. The Inner Jacket Diameter Range is 65-150 mm with an Outside Jacket Diameter Range of 65 to 165 mm. The Maximum Connector Length is 140 mm and the total Splice Installed Length is 2030 mm.  

HVSA-3-1523S-TECK supplied with a nominal cable range of 500-750 kcmil. It requires an Insulation Diameter minimum of 28 mm and a maximum of 41 mm. The Inner Jacket Diameter Range is 65-150 mm with an Outside Jacket Diameter Range of 65 to 165 mm. The Maximum Connector Length is 200 mm and the total Splice Installed Length is 2030 mm.   

HVSA-3-1523S-TECK supplied with a nominal cable range of 750-1000 kcmil. It requires an Insulation Diameter minimum of 32 mm and a maximum of 46 mm. The Inner Jacket Diameter Range is 65-150 mm with an Outside Jacket Diameter Range of 65 to 165 mm. The Maximum Connector Length is 200 mm and the total Splice Installed Length is 2030 mm.   

No comments:

Post a Comment