HVS-C-RJ
In-Line Heat Shrinkable Repair Splices
TE Connectivity’s Raychem introduces a new 15 kV and 25 kV repair splice, for use with either
Copper Tape Shield or Jacketed Concentric Neutral cables.
Copper Tape Shield or Jacketed Concentric Neutral cables.
This series of splices utilizes the new triple-extrusion Rayfit splice sleeve which provides high
recovery forces resulting in superior interfacial pressure, reduced shrink and installation time, and a
slimmer space-saving profile.
- One kit replaces two conventional splices for most repairs
- Splice includes extra long tin plated aluminum shearbolt connector
- Each kit contains all of the components required for the complete joint assembly
- All HVS joints have been qualified to the latest version of IEEE-404
HVS-C-RJ For Jacketed Concentric Neutral and Unjacketed Concentric Neutral Cables (-10 Series):
Rated for use at 15 kV
HVS-C-1512S-RJ-M4 is supplied for a Conductor Size range of #2-2/0 with a Maximum Jacket O.D. of 30 mm. The Min.-Max. Insulation Diameter is 17-24 mm including a Connector length of 440 mm and a Connector Diameter of 24 mm.
HVS-C-1512S-RJ-M5 is supplied for a Conductor Size range of 2/0-350 with a Maximum Jacket O.D. of 42 mm. The Min.-Max. Insulation
Diameter is 20-30 mm including a Connector length of 440 mm and a
Connector Diameter of 33 mm.
HVS-C-1513S-RJ-M7 is supplied for a Conductor Size range of 350-500 with a Maximum Jacket O.D. of 45 mm. The Min.-Max. Insulation
Diameter is 26-34 mm including a Connector length of 440 mm and a
Connector Diameter of 37 mm.
HVS-C-1514S-RJ-M8 is supplied for a Conductor Size range of 500-750 with a Maximum Jacket O.D. of 48 mm. The Min.-Max. Insulation
Diameter is 29-39 mm including a Connector length of 440 mm and a
Connector Diameter of 42 mm.
HVS-C-1514S-RJ-M9 is supplied for a Conductor Size range of 750-1000 with a Maximum Jacket O.D. of 58 mm. The Min.-Max. Insulation
Diameter is 34-43 mm including a Connector length of 440 mm and a
Connector Diameter of 46 mm.
Rated for use at 25 kV
HVS-C-2511S-RJ-M4 is supplied for a Conductor Size range of
#2-3/0 with a Maximum Jacket O.D. of 42 mm. The Min.-Max. Insulation
Diameter is 19-28 mm including a Connector length of 440 mm and a
Connector Diameter of 24 mm.
HVS-C-2512S-RJ-M5 is supplied for a Conductor Size range of 4/0-350 with a Maximum Jacket O.D. of 55 mm. The Min.-Max. Insulation
Diameter is 26-38 mm including a Connector length of 440 mm and a
Connector Diameter of 33 mm.
HVS-C-2513S-RJ-M8 is supplied for a Conductor Size range of 500-750 with a Maximum Jacket O.D. of 60 mm. The Min.-Max. Insulation
Diameter is 34-43 mm including a Connector length of 440 mm and a
Connector Diameter of 42 mm.
HVS-C-2514S-RJ-M9 is supplied for a Conductor Size of 1000 with a Maximum Jacket O.D. of 65 mm. The Min.-Max. Insulation
Diameter is 43-49 mm including a Connector length of 440 mm and a
Connector Diameter of 46 mm.
HVS-C-RJ For Copper Tape Shield, Wire Shield, UniShield and Lead Sheath Cables (-20 Series)
Rated for use at 15 kV
HVS-C-1522S-RJ-M4 is supplied for a Conductor Size range of
#2-2/0 with a Maximum Jacket O.D. of 30 mm. The Min.-Max. Insulation
Diameter is 17-24 mm including a Connector length of 440 mm and a
Connector Diameter of 24 mm.
HVS-C-1522S-RJ-M5 is supplied for a Conductor Size range of 2/0-350 with a Maximum Jacket O.D. of 42 mm. The Min.-Max. Insulation
Diameter is 20-30 mm including a Connector length of 440 mm and a
Connector Diameter of 33 mm.
HVS-C-1523S-RJ-M7 is supplied for a Conductor Size range of 350-500 with a Maximum Jacket O.D. of 45 mm. The Min.-Max. Insulation
Diameter is 26-34 mm including a Connector length of 440 mm and a
Connector Diameter of 37 mm.
HVS-C-1524S-RJ-M8 is supplied for a Conductor Size range of 500-750 with a Maximum Jacket O.D. of 48 mm. The Min.-Max. Insulation
Diameter is 29-39 mm including a Connector length of 440 mm and a
Connector Diameter of 42 mm.
HVS-C-1524S-RJ-M9 is supplied for a Conductor Size range of 750-1000 with a Maximum Jacket O.D. of 58 mm. The Min.-Max. Insulation
Diameter is 34-43 mm including a Connector length of 440 mm and a
Connector Diameter of 46 mm.
Rated for use at 15 kV
HVS-C-2521S-RJ-M4 is supplied for a Conductor Size range of
#2-3/0 with a Maximum Jacket O.D. of 42 mm. The Min.-Max. Insulation
Diameter is 19-28 mm including a Connector length of 440 mm and a
Connector Diameter of 24 mm.
HVS-C-2522S-RJ-M5 is supplied for a Conductor Size range of 4/0-350 with a Maximum Jacket O.D. of 55 mm. The Min.-Max. Insulation
Diameter is 26-38 mm including a Connector length of 440 mm and a
Connector Diameter of 33 mm.
HVS-C-2523S-RJ-M8 is supplied for a Conductor Size range of 500-750 with a Maximum Jacket O.D. of 60 mm. The Min.-Max. Insulation
Diameter is 34-43 mm including a Connector length of 440 mm and a
Connector Diameter of 42 mm.
HVS-C-2524S-RJ-M9 is supplied for a Conductor Size of 1000 with a Maximum Jacket O.D. of 65 mm. The Min.-Max. Insulation
Diameter is 43-49 mm including a Connector length of 440 mm and a
Connector Diameter of 46 mm.